Welcome: Shanghai cixi instrument CO.,LTD,it's a professional 35 years manufacturer of micro flow meter,ultrasonic flow meter,water flow meter,magnetic flow meter,turbine flow meter,vortex flow meter,coriolis flow meter,digital flow meter,thermal mass flow meter,liquid flow meter,gas flow meter,dosing pump,gear metering pump,level transmitter,level sensor etc.

Industry News

Home > News > Industry News >

Glue Micro Gear Flow Meter Manufacturer

      Shanghai Cixi is the first manufacturer of glue micro gear flow meter. The engineer is from Siemens, and it has obtained 2 invention patents. The product has obtained ISO, SGS, CE quality certification. Double the flow range of glue micro gear flowmeters within 0.5ML/MIN ~ 1000ML/MIN, to achieve stock supply, a real benchmarking enterprise in the automatic process control industry, and German quality. For detailed parameters and quotations, please contact winny:sales01@cxflowmeter.com
 
 
 
      Glue Micro Gear Flow Meter Product Description
 
     In terms of high temperature resistance and high pressure resistance, the micro flowmeter adopts the most advanced design in the world, so that the domestic micro flowmeter not only synchronizes with the international advanced level in quality, but also synchronizes with the international advanced level in high temperature resistance and high pressure resistance.

 
 
     CIXI micro flowmeter has 2 national invention patents. In the process of production quality control, starting from the purchase of raw materials, every production and precision processing link is carefully checked, and each micro flowmeter must be continuously calibrated before leaving the factory. . Each process of the micro-wheel flowmeter is strictly implemented in accordance with the ISO9001 quality management system, and the products have CE, SGS and other EU certifications.
 
Our company builds a world-class oval gear flow under the slogan of "German quality, Chinese price", and is truly a benchmark enterprise in the automation instrument industry.
 
 
Common fault reasons and troubleshooting methods for glue micro gear flowmeters
 
1. No signal from the flow sensor: the gear is stuck or the circuit is connected incorrectly or the circuit is damaged. Need to clean the gear and cavity, or reconnect the circuit correctly, or replace the circuit.
 
2. The flow error is too large: the actual flow range is lower than or much larger than the flow meter range. The flowmeter of the corresponding range needs to be selected.
 
3. Small flow error is too large: The flowmeter is installed in the wrong direction, and the best position is in and out.
 
4. The gear does not rotate: the gear is stuck by debris, and the gear and cavity need to be cleaned, and the filter should be cleaned or replaced.


sales01@cxflowmeter.com



 

PRODUCTS

CATEGORIES

CONTACT US

Contact:Leon

Tel: +86021-57635022

Email:info@cxflowmeter.com

Add:Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)